oxidized bitumen 90/15
Description of Oxidized Bitumen 90/15
At the bitumen production reactor, during air oxidation, a mixture of Vacuum Bottom (VB) and Vacuum Silas (VS) feedstocks undergoes a controlled process at a temperature between 200-300°C. This process oxidizes the hydrogen atoms in the bitumen molecule, resulting in polymerization with higher hydrocarbons. The final product, oxidized bitumen 90/15, has a softening point of 90°C and a penetration value of 15 dmm.
Gold Bitumen guarantees the quality of its oxidized Garid 90/15 through international inspections and quality control (QC) testing, ensuring compliance with ASTM standards.
Uses of Oxidized Bitumen 90/15
Oxidized Garid 90/15 is widely used in industries such as:
Table of Contents
Toggle- Chemicals, fuels, and coatings
- Road construction and pavement repair
- Roofing and waterproofing
- Adhesives and construction material additives
- Corrosion protection for metals
Application of Oxidized Garid 90/15
Before application, oxidized Garid 90/15 must be heated to twice its softening point to achieve the required flow and viscosity. Surfaces should be clean, dry, and free of debris, curing products, or irregularities.
Storage/Handling of Oxidized
Oxidized bitumen 90/15 has a shelf life of up to 10 years, even with repeated heating and cooling. Always refer to the Material Safety Data Sheet (MSDS) for safe handling instructions.
Packing of Oxidized Bitumen 90/15
Gold Bitumen offers multiple packing options to suit customer needs, including:
- Kraft bags
- Meltable plastic bags
- Drums
- Bulk containers
The product complies with ASTM standards, ensuring the desired softening point of 90°C and penetration value of 15 dmm.
Guaranty/Warranty of Blown Bitumen 90/15
GoldBitumen guarantees the quality of its oxidized Garid 90/15 through international inspections during shipment and strict quality control (QC) tests conducted before shipping. All products comply with ASTM/EN 13304:2009 standards.
Analysis of Garid 90/15
Property | Test Method | Unit | Specification |
---|---|---|---|
Specific Gravity @25°C | ASTM D70 | Kg/m³ | 1.05 approx. |
Penetration @25°C | ASTM D5 | mm/10 | 10-20 |
Softening Point | ASTM D36 | °C | 85-95 |
Ductility @25°C | ASTM D113 | cm | 1.5 min |
Loss on Heating | ASTM D6 | Wt. % | 0.2 max |
Flashpoint | ASTM D92 | °C | 250 min |
Solubility in CS2 | ASTM D4 | Wt. % | 99.5 min |
Spot Test | A.A.S.H.O T102 | — | Negative |